Bottle-Type FRP Cooling Towers in Pakistan

AKD Cooling Towers supplies, installs, repairs and maintains bottle-type FRP cooling towers for industrial and commercial applications. Our team reviews cooling requirements, operating conditions and site constraints before recommending a suitable tower, replacement part or service solution.

About Bottle-Type Cooling Towers

What Is a Bottle-Type Cooling Tower?

A bottle-type cooling tower is a round FRP cooling tower named for its circular, bottle-like external structure. “Bottle type” describes its physical shape and construction; it does not independently define the tower’s cooling capacity or complete operating arrangement. FRP is commonly used for the casing because it provides corrosion resistance and relatively lightweight construction. Its compact circular design can be useful where installation space is limited. Many bottle-type models operate as counterflow, induced-draft cooling towers with a top-mounted axial fan. These towers are commonly used for industrial processes, chillers and commercial HVAC systems.

How Does a Bottle-Type Cooling Tower Work?

A bottle-type cooling tower cools circulating water by distributing hot water over fill media while a fan moves ambient air through the tower.

  1. Hot circulating water enters the tower.
  2. A sprinkler or water-distribution system spreads the water.
  3. Water flows downward over PVC fill media.
  4. Ambient air enters through the lower air-inlet area.
  5. A top-mounted fan draws air upward.
  6. Air and water move in opposite directions.
  7. A small portion of the water evaporates.
  8. Evaporation removes heat from the remaining water.
  9. Cooled water collects in the bottom basin.
  10. The water returns to the industrial process or HVAC system.

Counterflow means water moves downward while air moves upward.

Induced draft means a discharge-side fan pulls air through the tower.

Evaporative cooling removes heat by evaporating a small portion of the circulating water.

Cooling Tower Components

Main Components of a Bottle-Type Cooling Tower

Axial Fan and Fan Blades

The axial fan moves air through the tower. Blade balance, pitch, clearance and condition affect airflow, vibration, noise and cooling performance.

Electric Motor

The electric motor powers the fan. Its rating must match the fan design and operating requirements.

Cold-Water Basin

The basin collects cooled water before it returns to the process or chiller circuit. It should remain free from excessive scale, sediment and biological buildup.

FRP Body and Casing

The FRP casing forms the external body and protects the internal components. Material quality, installation and maintenance affect its service life.

Water-Distribution System

A rotary sprinkler or spray-nozzle arrangement distributes hot water over the fill media. Even water distribution supports effective cooling.

PVC Fill Media

PVC fill media increases the contact area and contact time between water and air. Fill selection should consider water temperature, water quality and contamination risk.

Drift Eliminators

A drift eliminator reduces water droplets carried out with the discharge air.

Air-Inlet Section

The lower air-inlet section allows ambient air to enter the tower. Blockages or poor site clearance can restrict airflow.

Float Valve and Make-Up Water System

The float valve controls make-up water and maintains the required basin level.

Support Frame and Connections

The support structure carries the tower load. Inlet, outlet, drain, overflow and make-up connections connect the tower to the circulating-water system.

Key Features

Key Features of Bottle-Type FRP Cooling Towers

Corrosion-resistant FRP construction

Counterflow air-and-water movement

Compatibility with process and HVAC systems

Access to commonly serviced spare parts

Fan & motor

PVC fill media

Sprinkler head

FRP body & basin

AKD Technical Catalogue

Bottle Type Cooling Towers

Bottle Type Cooling Towers
AKD ModelNominal Capacity TRWater FlowH (in)D (in)Outlet (in)Inlet (in)Overflow (in)Drain (in)MotorFan Dia. (in)Air Volume (CFM)
AKD-20260 L/min764222110.75 HP245000
AKD-25325 L/min764822112 HP276250
AKD-30390 L/min705422112 HP287500
AKD-40420 L/min685422112 HP3010000
AKD-50560 L/min74662.52.5112 HP3412500
AKD-60720 L/min74682.52.5112 HP3615000
AKD-70775 L/min74842.52.5113 HP3817500
AKD-80800 L/min799244113 HP4220000
AKD-1001350 L/min799844115 HP4725000
AKD-1251550 L/min8510644115 HP5431250
AKD-1501850 L/min8712055115 HP6037500
AKD-1752000 L/min9012666215 HP6843750
AKD-2002200 L/min9713666227.5 HP7150000
AKD-2252300 L/min11714466227.5 HP7256250
AKD-2503100 L/min125156662210 HP7462500
AKD-3003600 L/min125166882210 HP8675000
AKD-3503800 L/min131166882210 HP9687500
AKD-4005200 L/min133200882215 HP102100000
AKD-5006000 L/min153222882215 HP118125000
AKD-6007800 L/min15324010104220 HP132150000
AKD-7008750 L/min17026510104220 HP136175000
AKD-80010000 L/min17228210104225 HP142200000
AKD-100012500 L/min1943061224330 HP148250000

Final selection and technical specifications are confirmed by AKD after review of operating and site conditions.

Bottle-type cooling tower configurations – standard, extended basin and high capacity
Technical Details

Bottle-Type Cooling Tower Technical Detail

The technical details below summarise the typical construction, airflow arrangement, cooling method, applications and maintenance requirements of bottle-type FRP cooling towers. Final configuration can vary according to cooling duty, equipment design and site conditions.

Classification

Packaged mechanical-draft cooling tower

Shape

Round or circular

Common material

Fibre-reinforced plastic (FRP)

Airflow arrangement

Usually induced draft

Water and air movement

Usually counterflow

Cooling method

Evaporative cooling

Installation type

Packaged, project-specific installation

Common applications

Process equipment, chillers, compressors and HVAC systems

Maintenance needs

Basin and fill cleaning, water-distribution checks, fan inspection and descaling

AKD services

Selection, supply, installation, repair, maintenance and spare parts
Bottle-Type Cooling Tower FAQs

Frequently Asked Questions

Yes. A correctly selected bottle-type cooling tower can serve industrial chillers, compressors, manufacturing equipment, process cooling and commercial HVAC systems. Suitability depends on the required heat load, water-flow rate, inlet and outlet temperatures, water quality and available installation space.

 

Cooling-tower selection normally requires the circulating water-flow rate, hot-water inlet temperature, required cold-water outlet temperature and local wet-bulb temperature. Operating hours, process heat load, water quality, site conditions, available space and noise requirements should also be reviewed.

The price depends on cooling capacity, tower dimensions, FRP specification, fill media, fan, motor, water-distribution system, delivery location and installation requirements. An accurate price requires a project-specific quotation based on the customer’s operating and site conditions.

Maintenance frequency depends on operating hours, water quality, environmental dust and equipment condition. The basin, fill media, water-distribution system, fan, motor and drift eliminator should be checked regularly to prevent scale, blockage, vibration and reduced cooling performance.

Yes. Many bottle-type cooling towers can be repaired or refurbished. Common work includes FRP crack repair, basin leak repair, fill replacement, sprinkler or nozzle replacement, fan balancing, motor servicing and drift-eliminator replacement. An inspection should determine whether repair or complete replacement is more practical.

Request a Bottle-Type Cooling Tower Quote

Need a bottle-type FRP cooling tower for a new or existing system? Share your water-flow rate, hot- and cold-water temperatures, project location, application and available installation space. Our technical team will review the details and recommend a suitable tower configuration and next step.